Opened 16 years ago

Last modified 16 years ago

#1077 closed defect

Lowess normalization broken — at Version 1

Reported by: Jari Häkkinen Owned by: Jari Häkkinen
Priority: blocker Milestone: BASE 2.7.2
Component: coreplugins Version:
Keywords: Cc:

Description (last modified by Jari Häkkinen)

This problem affects all versions of BASE2.

As pointed out in the BASE users mailing list (http://www.mail-archive.com/basedb-users@lists.sourceforge.net/msg01478.html) there is a flaw in the lowess plug-in shipped with BASE. Users using the original BASE1 distributed lowess plug-in with the Base1PluginExecuter wrapper are not affected.

The fix is a simple one line change but affects all bioassays normalized with lowess and consequently all analysis following a lowess normalization must be redone. The changes to be expected to analysis results varies with raw data quality, where good quality raw data will have little effect from the miscalculation in the lowess plug-in.

Change History (1)

comment:1 by Jari Häkkinen, 16 years ago

Description: modified (diff)
Owner: changed from everyone to Jari Häkkinen
Status: newassigned